Peristaltic metering pump · 0.063 to 500 mL/min
Every drop,
accounted for.
Chemical metering across an 8,000:1 range on a single tube, with no valves to clog and no seals to leak. Proven dosing neat polymer on the 6PSevo feeder, and soon on IO-Link.

- 8,000:1
- Turndown on one tube
- 500mL/min
- Maximum flow (7.925 gph)
- 12,000cP
- Maximum viscosity
- IP66
- Enclosure
01 / The lineup
One pump, three ways to run it
The same pump head and drive, from inside a 6PSevo feeder to a device on your own network.

Corda 30
CRD-30S-BOn every 6PSevo feeder
The metering pump on Excell's 6PSevo polymer feeders, driven and monitored by the feeder's Cortex 7 controller.
- Start, stop and speed from the Cortex 7
- Stall and drive-fault alarms on the touchscreen
- Volume pumped, run-time and revolution counters

Corda 30 IO-Link
CRD-030S-IA pump that reports what happens inside it
A controller of its own inside the pump, on a single M12 cable. Flow set and read in mL/min, with cover, leak, stall and power status as data.
- Flow setpoint and feedback in 0.01 mL/min
- Cover-open and liquid-in-head stops of its own
- Settings kept in the port for a plug-and-play swap
In designCorda Standalone
No feeder required
The same pump head and drive with its own controls, for skids and plants that don't have a Cortex controller.
- The Corda 30's pump head and drive
- Its own local controls
- Tell us what your application needs
02 / Corda 30 IO-Link · CRD-030S-I
The first peristaltic metering pump with native IO-Link.
Most metering pumps are blind: a speed signal in, maybe a fault contact out. The Corda 30 IO-Link has its own controller inside. Set the flow in mL/min, and the pump tells you what it delivered, how hard the motor is working, and why it stopped.
One standard M12 cable carries the data and the pump's logic power. Swap a pump, and the IO-Link master gives the new one its settings and calibration back.
Reported every cycle

03 / Why peristaltic
Nothing in the way of the fluid
Thick, sticky or aggressive, the chemical never touches anything but the tube. That's why a peristaltic pump meters what others clog on.
01
No valves, no seals
The chemical touches only the tube and its end fittings. There are no check valves to clog and no dynamic seals to leak.
02
Self-priming, runs dry
Primes against full discharge pressure and lifts 30 ft of water. Dry running while priming does no harm.
03
One tube, full range
0.001 to 7.925 gph on a single tube size. No tube changes to move between applications.
04
Slow for long tube life
60 RPM maximum at the rotor. Occluding rollers on sealed stainless bearings, with guide rollers that keep the tube centered.
05
Tool-free tube change
Four thumb nuts, a clear cover, and a tube with its fittings attached. Inspect the tube and rollers through the cover while the pump runs.
06
Positive shut-off
With the pump stopped, a roller keeps the tube occluded and holds back flow in either direction.
04 / Applications
Where Corda pumps
The polyurethane tube handles a wide range of chemicals. Tell us what you're dosing and we'll confirm the tube and fittings for it.
Water and wastewater
Sodium and calcium hypochlorite, ferric chloride and sulfate, alum, potassium permanganate and fluorosilicic acid, and the neat emulsion polymer Corda has been dosing on Excell's 6PSevo feeders.
Industrial process
Oils, lubricants and fuels, glycols, detergents, brines and dilute acids, with a pump that self-primes, runs dry and meters down to 0.063 mL/min.
OEM equipment and skids
One compact, IP66 pump with an 8,000:1 range, so one model can cover a whole product line. Talk to us about integration.
Tube rated by Saint-Gobain for, among others
05 / Coming next
Corda Standalone
The Corda 30's pump head and drive with controls of its own, for skids, OEM packages and plants that don't have a Cortex controller or an IO-Link master.
It's being designed now. If you have an application in mind, tell us what it needs.
Tell us about your application
Meter with confidence.
Talk to the team that builds the pump. Ask about the Corda 30 on your 6PSevo, your own chemical and application, or early access to the IO-Link pump.