In developmentCRD-030S-I

Corda 30
IO-Link

The first peristaltic metering pump with native IO-Link.

Today's Corda is driven step by step from the controller, and nothing inside the pump knows about the pump. The IO-Link Corda has a controller of its own. It runs its motor, watches its sensors, enforces its own safety stops and reports all of it as data.

Corda 30 IO-Link with its housing shown translucent and its controller board inside

01 / Plug and produce

A metering pump that behaves like a sensor

One cable and no analog scaling. The pump shows up on your IO-Link master like any other device on it.

The back of the Corda 30 IO-Link, with its M12 IO-Link connector
M12 · IO-Link · COM3

01

Plug in one M12 cable

A standard A-coded IO-Link cable from any port. It carries the data and the 24 V that runs the pump's own controller.

02

Set flow in mL/min

The pump holds its own calibration and turns flow into rotor speed itself. 0.01 mL/min resolution at any turndown, with no 4-20 mA scaling.

03

Read what happened

Flow delivered, motor torque and eight status bits every cycle; events for every stop; counters for tube life and running hours.

04

Swap without setup

IO-Link Data Storage keeps the pump's settings and calibration in the port. A replacement pump gets them back when it's plugged in.

02 / Architecture

Logic on the link, power on its own

The pump's controller runs from the IO-Link port. The servo has its own 48 V supply inside the pump. With mains off, the pump stays on the link and reports no motor power instead of disappearing.

IO-Link master

Cortex 7 IO-Link card

On the 6PSevo

Any IO-Link master

Through the pump's IODD

M12 · L+ · C/Q · L−

Corda 30 IO-Link

Pump controller

IO-Link device · runs on the port's 24 V

Sensors

Cover · liquid in head · enclosure air

Servo motor

Speed out · torque back

48 V motor supply

From mains, measured by the controller

03 / Safety in the pump

Its own stops, in its own firmware

These stops hold with the link down or the controller misconfigured.

The pump head behind its clear cover: rotor, rollers and tube

Nothing restarts by itself. After a stop, the pump runs again only on the controller's Reset fault, once the cause has gone. Closing the cover never starts it: a guard closing must not start a machine (ISO 14119).

01

Cover open

A sensor on the front cover. With the cover off, the pump stops, whatever the controller asks.

02

Liquid in the pump head

An optical prism sensor in the head's drain sees a split tube. Optical, so it also sees liquids that conduct too poorly for a conductive probe, such as neat polymer.

03

Stall

Torque from the servo, averaged and timed: the same stall rule the 6PSevo uses today. Set it to stop the pump or to report only.

04

Link lost

If the master's messages stop, or it marks the outputs invalid, the pump stops. Only a new Run from the controller starts it again.

04 / On the wire

Process data, settings and events

From the draft IODD. Details may change before release.

Process data in

pump to controller · 10 octets
ValueSizeNote
Flow being delivered32 bit0.01 mL/min
Motor torque16 bit0.1 %, from the servo's HLFB
Runningbit
Cover openbitThe pump has stopped
Liquid in pump headbitThe pump has stopped
Stallbit
Motor faultbit
No motor powerbitReported as such, not as a stall
Tube change duebitFrom the tube-life setting
Setpoint limitedbitAsked for more than the maximum speed

Process data out

controller to pump · 5 octets
ValueSizeNote
Flow setpoint32 bit0.01 mL/min, 0 to 500 mL/min
Runbit
Reset faultbitOn its rising edge

Communication

ItemValue
ConnectorM12, A-coded, 4-pin
Transmission rateCOM3, 230.4 kbit/s
Minimum cycle time2 ms
Process data10 octets in, 5 octets out
DescriptionIODD (IO-Link 1.1)
Logic powerFrom the port's L+, 24 V

Settings

ISDU
SettingValue
CalibrationmL per revolution of the head (nominally 8.333)
Maximum speedIn 0.1 RPM, 60 RPM at most
Stall actionReport only, or stop
Tube lifeRevolutions, for a tube-change reminder

Counters and readings

  • Revolutions since the tube was changed
  • Total revolutions
  • Running hours
  • Motor supply voltage
  • Tube changed system command resets the tube's count

Events

  • Cover openError
  • Liquid in pump headError
  • Motor stallError
  • Motor faultError
  • No motor powerError
  • Tube change dueWarning

Firmware updates

Updated over the same cable

New pump firmware goes in over IO-Link, signed and checked before it runs. No laptop at the pump and no opening the enclosure.

With Cortex 7

First on the 6PSevo

The Cortex 7 controller's IO-Link card brings the pump's events into its alarms, and its counters onto the maintenance screen. Any IO-Link master can read the pump through its IODD.

Be first on IO-Link.

The Corda 30 IO-Link is in development. Tell us about your application and we'll keep you up to date on availability and field trials.